ML GRATINGS ML gratings are original rulings or replicas that are normally used as end reflectors for tuning molecular lasers. Original gratings are ruled directly into an aluminum coating deposited on a kanigen coated copper substrate, resulting in an inherently higher damage threshold and are recommended for use with high powered molecular lasers.
The output wavelength of a molecular or dye laser can be tuned by rotating a Littrow mounted grating around an axis parallel to the grooves. The grating equation:
nl = d(sin i + sin i’)
where n is the order of diffraction, l is the diffracted wavelength, d is the grating constant (the distance between successive grooves), i is the angle of incidence measured from the normal and i’ is the angle of diffraction measured from the normal, reduces to nl = 2d sin i for the Littrow configuration.
The angle of incidence (i) is adjusted to select the output wavelength while creating a narrow gain profile.
Because the ML series of gratings are designed for peak polarized efficiency, the groove angle is not equivalent to the Littrow blaze angle of the grating. As a result, when using a He-Ne laser for preliminary grating alignment, the brightest He-Ne order will not correspond to the blaze wavelength of the grating. The grating must be aligned using the calculated He-Ne order that corresponds to the wavelength of interest, regardless of its relative intensity.
The blaze arrow marked on the side or back of the grating should be oriented as shown above.
Typical efficiency curves illustrate that, in all cases, orienting the polarization of the E vector (P-Plane) perpendicular to the grooves (E ^) increases the efficiency over a specific wavelength region. This should be considered when optimizing the figure of merit (Q) of a cavity, particularly when it is polarized by auxiliary components such as Brewster angle windows.
COATING ML gratings can be overcoated with gold, increasing the reflectivity at 10.6 microns by approximately 1%, but the damage threshold in high power applications may be reduced. No damage threshold minimums apply for overcoated gratings.
ML Series Gratings - Original And Replicated ML gratings are normally used as end reflectors for tuning molecular lasers. Original gratings are ruled directly into an aluminum coating deposited on a kanigen coated copper substrate, resulting in an inherently higher damage threshold than the replicas which are replicated onto a pyrex substrate.
Squares
SIZE
25 x 25 mm
30 x 30 mm
50 x 50 mm
58 x 58 mm
Eff Curve
MODEL NO.
ORIGINAL CAT NO.
REPLICA CAT NO.
ORIGINAL CAT NO.
REPLICA CAT NO.
ORIGINAL CAT NO.
REPLICA CAT NO.
ORIGINAL CAT NO.
REPLICA CAT NO.
ML-301
5-3012
5-3112
5-3019
5-3119
5-3015
5-3115
5-3016
5-3116
ML-302
5-3022
5-3122
5-3029
5-3129
5-3025
5-3125
5-3026
5-3126
ML-303
5-3032
5-3132
5-3039
5-3139
5-3035
5-3135
5-3036
5-3136
ML-304
5-3042
5-3142
5-3049
5-3149
5-3045
5-3145
5-3046
5-3146
ML-401
5-4012
5-4112
5-4019
5-4119
5-4015
5-4115
5-4016
5-4116
ML-402
5-4022
5-4122
5-4029
5-4129
5-4025
5-4125
5-4026
5-4126
ML-501
5-5012
5-5112
5-5019
5-5119
5-5015
5-5115
5-5016
5-5116
ML-502
5-5022
5-5122
5-5029
5-5129
5-5025
5-5125
5-5026
5-5126
ML-601
5-6012
5-6112
5-6019
5-6119
5-6015
5-6115
5-6016
5-6116
ML-701
5-7012
5-7112
5-7019
5-7119
5-7015
5-7115
5-7016
5-7116
PRICE($)*
710.00
180.00
1,100.00
190.00
1,430.00
290.00
1.820.00
350.00
* Prices are in USD and are list prices only.
Diameters
SIZE
25 mm DIA.
38 mm DIA.
50 mm DIA.
Eff Curve
MODEL NO.
ORIGINAL CAT NO.
REPLICA CAT NO.
ORIGINAL CAT NO.
REPLICA CAT NO.
ORIGINAL CAT NO.
REPLICA CAT NO.
ML-301
5-3011
5-3111
5-3017
5-3117
5-3014
5-3114
ML-302
5-3021
5-3121
5-3027
5-3127
5-3024
5-3124
ML-303
5-3031
5-3131
5-3037
5-3137
5-3034
5-3134
ML-304
5-3041
5-3141
5-3047
5-3147
5-3044
5-3144
ML-401
5-4011
5-4111
5-4017
5-4117
5-4014
5-4114
ML-402
5-4021
5-4121
5-4027
5-4127
5-4024
5-4124
ML-501
5-5011
5-5111
5-5017
5-5117
5-5014
5-5114
ML-502
5-5021
5-5121
5-5027
5-5127
5-5024
5-5124
ML-601
5-6011
5-6111
5-6017
5-6117
5-6014
5-6114
ML-701
5-7011
5-7111
5-7017
5-7117
5-7014
5-7114
PRICE($)*
760.00
240.00
1,200.00
365.00
1,565.00
495.00
* Prices are in USD and are list prices only.
ML Series Gratings - Original And Replicated ML gratings are normally used as end reflectors for tuning molecular lasers. Original gratings are ruled directly into an aluminum coating deposited on a kanigen coated copper substrate, resulting in an inherently higher damage threshold than the replicas which are replicated onto a pyrex substrate.
Rectangles
SIZE
12.5 x 25 mm
25 x 50 mm
1 x .825
Eff Curve
MODEL NO.
ORIGINAL CAT. NO.
REPLICA CAT. NO.
ORIGINAL CAT. NO.
REPLICA CAT. NO.
ORIGINAL CAT. NO
REPLICA CAT. NO.
ML-301
5-3610
5-3810
5-3013
5-3113
5-3018
5-3118
ML-302
5-3620
5-3820
5-3023
5-3123
5-3028
5-3128
ML-303
5-3630
5-3830
5-3033
5-3133
5-3038
5-3138
ML-304
5-3640
5-3840
5-3043
5-3143
5-3048
5-3148
ML-401
5-4610
5-4810
5-4013
5-4113
5-4018
5-4118
ML-402
5-4620
5-4820
5-4023
5-4123
5-4028
5-4128
ML-501
5-5610
5-5810
5-5013
5-5113
5-5018
5-5118
ML-502
5-5620
5-5820
5-5023
5-5123
5-5028
5-5128
ML-601
5-6610
5-6810
5-6013
5-6113
5-6018
5-6118
ML-701
5-7610
5-7810
5-7013
5-7113
5-7018
5-7118
Price ($)*
575.00
120.00
995.00
230.00
710.00
130.00
* Prices are in USD and are list prices only.
COATINGS
Protective overcoatings that maintain or enhance reflectivity in the UV, Visible and IR regions are available for an additional charge.
AU-3 (Replica Grating Overcoat)
$60.00
AU-4 (Original Grating Overcoat)
$60.00
Legend
* All gratings are measured in the Littrow mounting configuration
* All gratings utilize an aluminum (Al ) reflective coat